EZ1005 Chloride Analyser, 1 stream, Modbus RS485

EZ1005 Chloride Analyser, 1 stream, Modbus RS485
Productnr.: EZ1005.99001C02
EUR Prijs: Neem contact op

Specificaties

Aantal monsterstromen: 1 stream

Optional:
1 to 8 streams
Afmetingen(H x B x D): 690 mm x 465 mm x 330 mm
afvoerslang: Atmospheric pressure, vented, min. Ø 64 mm
Alarm: 1x malfunctioning, 4x user-configurable, max. 24 VDC/0.5 A, potential free contacts
Beschermingsklasse: Analyser cabinet: IP55 / Panel PC: IP65
Certificering: CE compliant / UL certified
Cyclustijd: 10 min (dilution + 5 min)
Detectiegrens: ≤ 1 mg/L
Digital outputs: Modbus RS485
Earth connection: Dry and clean earth pole with low impedance (< 1 Ohm) using an earth cable of > 2.5 mm²
Garantie: 2 jaar
Gewicht : 25 kg
Instrument air: Dry and oil free according to ISA-S7.0.01-1996 quality standard for instrument air
interferenties: Substances in amounts normally found in potable water will likely not interfere. Bromide, iodidie and cyanide register as equivalent chloride concentrations. Sulfide, thiosulfate and sulfite interfere but can be removed by treatment with hydrogen peroxide. Orthophosphate > 25 mg/L interferes by precipitating as silver phosphate. Iron > 10 mg/L interferes. Large amounts of colour and turbidity interfere. Fats, oil, proteins, surfactants and tar.
Kalibratie: Automatic, 2-point; frequency freely programmable
Materiaal: Hinged part: Thermoform ABS, door: plexiglass
Wall section: Galvanised steel, powder coated
Meetbereik: 1 - 10 mg/L Cl-

Optional:
4 - 40 mg/L Cl- (with internal dilution)
8 - 80 mg/L Cl- (with internal dilution)
100 - 1000 mg/L Cl- (with internal dilution)
Meetmethode: Colorimetric measurement of turbidity at 480 nm after silver chloride (AgCl) precipitation, based on standard method APHA 4500-Cl (B)
Monster druk: By external overflow vessel
Monster kwaliteit: Maximum particle size 100 µm, < 0.1 g/L; Turbidity < 50 NTU
Monster stroomsnelheid: 100 - 300 mL/min
Monster temperatuur: 10 - 30 °C
Omgevingstemperatuur: 10 - 30 °C ± 4 °C deviation at 5 - 95% relative humidity (non-condensing)
Parameter: Chloride
Precisie: Better than 2% full scale range for standard test solutions
Reagent Requirements: Keep between 10 - 30 °C
Stroom: 110 - 220 VAC, 2 A, 50/60Hz
Max. power consumption: 150 VA
Other voltages available on request
Uitgang: Modbus RS485

Optional:
Active 4 - 20 mA max. 500 Ohm load, 1 to 8 outputs
RS232, Modbus TCP/IP
Validation: Automatic; frequency freely programmable