CL17sc colorimetrische chlooranalyser met drukregelaar-installatiekit, zonder reagentia

CL17sc colorimetrische chlooranalyser met drukregelaar-installatiekit, zonder reagentia
Productnr.: 8574500
Prijs per eenheid Neem contact op
Beschikbaar

Maintenance made easy

The CL17sc reduces your routine maintenance touch time with programmable alerts, simplified tubing replacement, and step-by-step maintenance instructions.

Peace of mind through comprehensive diagnostics

With upgraded features like a flow meter, colorimeter window, multi-colour status light, and predictive diagnostic software, you know your instrument is operating as intended.

Expanded connectivity. Increased flexibility.

By pairing the CL17sc with Hach’s SC controller platform, your options increase significantly: internal data logging; external analogue and digital communication alternatives; and multi-parameter instrument flexibility.

The CL17sc is compliant with US EPA regulation 40 CFR 141.74. Both Method 4500-CL G and Method 334.0 can be used for measuring residual chlorine in drinking water.

Wat zit er in de doos

CL17sc-chlooranalyser met drukregelaar-installatiekit en Europese gebruikershandleiding.
Hach SC-controller en reagentia zijn niet inbegrepen, ze worden afzonderlijk verkocht.

Specificaties

Afmetingen(H x B x D): 342 mm x 329 mm x 177 mm
afvoerslang: ½-inch ID flexible hose
Alerts: Lage en hoge chloorgehaltes. Vuile kuvet. Lage en hoge monsterflow.
Bedrijfsomstandigheden: 0 - 90% relative humidity, non-condensing
Beschermingsklasse: IP66
Bevestingsstijl: Wall mount
Certificering: CE compliant with: EN 61326-1, CISPR 11, EN 50581
ACMA RCM
South Korea KC Certificate
North America: FCC Supplier’s Declaration of Conformance, IEC/EN 60529, ICES-003
Controller compatibiliteit: SC200, SC1000, SC4500. All controllers sold separately
Cyclustijd: 2.5 minutes
Detectiegrens: 0.03 mg/L
Garantie: 24 maanden
Gewicht : 4.1 kg
Installation Kit: Installatiekit voor drukregelaar
interferenties: Other oxidising agents such as bromide, chlorine dioxide, permanganate, and ozone will cause a positive interference. Hardness must not exceed 1,000 mg/L CaCO₃.
Lichtbron: LED, measurement at 510 nm, 1 cm light pathlength
Lucht spoeling: Optional with 3/8-inch quick-connect fitting and tubing; 0.003 m3/min at 1.38 bar maximum
Meetbereik: 0 - 10 mg/L Cl₂
Monster stroomsnelheid: 60 - 200 mL/min through the instrument
Monster temperatuur: 5 - 40 °C
Monster voorwaarden: Y-strainer filtration with 40-mesh screen or higher
Nauwkeurigheid: ± 5% or ± 0.04 mg/L (whichever is greater) from 0 - 5 mg/L Cl₂
± 10% from 5 - 10 mg/L Cl₂
Omgevingstemperatuur: 5 - 40 °C
Parameter: Chlorine, free; Chlorine, total residual
Reagens: 0.5 L of buffer solution and 0.5 L of indicator solution in 31 days
Stroom vereisten (Voltage): 12 VDC, 400 mA maximum (supplied by the controller)
Toevoer: ¼-inch OD polyethylene tube, quick-disconnect fitting
Voordruk: 0.3 - 5.2 bar supplied to Y-strainer
0.1 - 0.3 bar supplied to analyser
Wat zit er in de doos: CL17sc-chlooranalyser met drukregelaar-installatiekit en Europese gebruikershandleiding.
Hach SC-controller en reagentia zijn niet inbegrepen, ze worden afzonderlijk verkocht.